此体系为防腐在线取样装配。此体系为防腐在线取样装配。取样物料打仗各部件均接纳里衬PFA、衬氟材质,到达防腐目标,四氟吸料管配套拔出管(衬氟/搪玻璃材质)浸于釜内料液以下,增添其进程的不变性。隔阂泵以干净庄缩氛围为能源,物料在取样体系中构成闭环轮回回路,进程快速、宁静、无净化。 This system is on-line anti-corrosive sampling device. The part in contact with medium is lined with PFA or Fluorine to achieve the purpose of anti-corrosion. The Teflon suction pipe matched with the insertion pipe (fluorine lined / glass lined) is immersed below the medium liquid in the vessel to increase the stability of the process. The diaphragm pump is powered by clean compressed air and the sample flows in a closed circulation loop in the sampling system, which is fast, safe and pollution-free.
取样器装配及取样步骤: Sample Installation and Sampling Steps
装配步骤:
Installation procedure
1.将(拔出管)装配到反映盆响应管口上,紧固螺栓。
Install (the insertion pipe} on the corresponding nozzle of the reactor and fasten the bolts
2.将取样体系下端(底座)与(隔阂阀1)拆分,将(底座)装配到(拔出管)上端。
Separate the lower end (base) of the sampling system from (diaphragm valve 1), and install (base) to the upper end of (insertion pipe)
3.将四氟外翻边(吸料管)装入(底座)内腔,四氟(吸料管)外翻边处于(阀座)密封面处符合。
Put the Teflon outer flanging(suction pipe) into the inner cavity of the (base), and the Teflon outer flange of (the suction pipe) is matched at the sealing surface of the (valve seat)
4.将其他取样体系主体与其毗连紧固,保障(底座)密封处压紧、无泄露。
Connect and tighten the rest of the sampling system body to ensure that the sealing part of (base} is tight and without leakage.
取样步骤:
Sampling procedure
1开机前确认、查抄:Confirm and check before starting
a:一切隔阂阀处于封闭状况。
All diaphragm valves are closed
b:取样体系内、外无剩余物,视镜无破坏。
There is no residue inside and outside the sampling system, and no damage to the sightglass
b:隔阂泵用0.2~0.3 MPa干净气源。
File the diaphragm pump with 0.2~0.3 MPa clean air pressure.
c:反吹用0.2~0.3 MPa氮气气源。
0.2~0.3 MPa nitrogen gas source is used for back blowing
d:备用150/250ml硼硅玻璃取样瓶1支。
One spare 150/250 ml borosilicate glass sampling bottle is needed
2.轮回回路: Circulation Loop:
a:翻开(阀门1)——翻开(阀门2)。
Open (valve 1) -- open (valve 2)
b:翻开(隔阂泵)。泵任务运行。
Open (diaphragm pump). The pump works
c:察看(视镜)。窗口内布满物料,同时构成取样轮回回路状况。
Observe (sightglass).The window is filled with medium, and a sampling ciculation loop state is formed at the same time.
3.取样:Sampling
a:按压(取样阀手柄)。察看取样瓶量剂,当令松开取样阀手柄。
Press (sampling valve handle) Observe the dosage of the sampling bottle and release the handle of the sampling valve in time.
b:封闭(隔阂泵)。Turn off (diaphragm pump).
c:取样瓶内排气进程。
The exhausting process in the sampling bottle.
c1:当罐内常压时翻开(隔阂阀3)-封闭 (隔阂阀3)。
When the tank is with atmospheric pressure: open (diaphragm valve 3) - close (diaphragm valve 3).
c2:当罐内≤0.2MPa时:翻开(四氟针型阀)-封闭(四氟针型阀)。
When the pressure in the tank is less than or equal to 0.2MPa open (Teflon needle valve) - close (Teflon needle valve).
注 指导排挤无害气体到宁静存贮装配中。
Note: discharge the harmful gases to a safe storage device.
d:取下(取样瓶)密封瓶口----装入(备用取祥瓶)。
Remove the (sampling bottle) and seal the bottle mouth - put in (spare sampling bottle).
e:翻开(隔阂阀4)----翻开(氮气)将体系内剩余物料反吹盆内——封闭(隔阂阀4)。
Open (diaphragm valve 4) - make (nitrogen) to blow the residual medium in the system back into the vessel - close (d闭 phragm valve 4).
f:封闭(隔阂阀2)----封闭(隔阂阀1)。
Close (diaphragm Valve 2) - Close (diaphragm Valve 1)
g:取样竣事。
Sampling complete.
澳门金狮
带主动取样体系洗濯进程申明: DescrlptIon of the C|eanlng Pocess of the Reactor with Aut omatic Samphng System:
在停止全部澳门金狮
的洗濯进程中,能够根据以上取样步骤描写停止取样体系外部洗濯、 吹扫。
During the cleaning process of the whole reacto,the internal cleaning and purging of the sampling system can be car ied out according to the above sampling steps.